Voici les éléments 1 - 10 sur 71
  • Publication
    Accès libre
    Absolute frequency referencing in the long wave infrared using a quantum cascade laser frequency comb
    (2022-4-4) ;
    Gianella, Michele
    ;
    Jouy, Pierre
    ;
    Kapsalidis, Filippos
    ;
    Shahmohammadi, Mehran
    ;
    Beck, Mattias
    ;
    ; ;
    Hugi, Andreas
    ;
    Faist, Jérôme
    ;
    Emmenegger, Lukas
    ;
    ;
    Optical frequency combs (OFCs) based on quantum cascade lasers (QCLs) have transformed mid-infrared spectroscopy. However, QCL-OFCs have not yet been exploited to provide a broadband absolute frequency reference. We demonstrate this possibility by performing comb-calibrated spectroscopy at 7.7 µm (1305 cm−1) using a QCL-OFC referenced to a molecular transition. We obtain 1.5·10−10 relative frequency stability (100-s integration time) and 3·10−9 relative frequency accuracy, comparable with state-of-the-art solutions relying on nonlinear frequency conversion. We show that QCL-OFCs can be locked with sub-Hz-level stability to a reference for hours, thus promising their use as metrological tools for the mid-infrared.
  • Publication
    Accès libre
    Coherently-averaged dual comb spectrometer at 7.7 µm with master and follower quantum cascade lasers
    (2021-6) ; ;
    Terrasanta, Giulio
    ;
    ; ;
    Gianella, Michele
    ;
    Jouy, Pierre
    ;
    Kapsalidis, Filippos
    ;
    Shahmohammadi Mehran, Mehran
    ;
    Beck Matthias, Matthias
    ;
    ;
    Faist, Jérôme
    ;
    Emmenegger, Lukas
    ;
    ;
    Hugi, Andreas
    ;
    We demonstrate coherent averaging of the multi-heterodyne beat signal between two quantum cascade laser frequency combs in a master-follower configuration. The two combs are mutually locked by acting on the drive current to control their relative offset frequency and by radio-frequency extraction and injection locking of their intermode beat signal to stabilize their mode spacing difference. By implementing an analog common-noise subtraction scheme, a reduction of the linewidth of all heterodyne beat notes by five orders of magnitude is achieved compared to the free-running lasers. We compare stabilization and post-processing corrections in terms of amplitude noise. While they give similar performances in terms of signal-to-noise ratio, real-time processing of the stabilized signal is less demanding in terms of computational power. Lastly, a proof-of-principle spectroscopic measurement was performed, showing the possibility to reduce the amount of data to be processed by three orders of magnitude, compared to the free-running system.
  • Publication
    Accès libre
    Compact rubidium-stabilized multi-frequency reference source in the 1.55-μm region
    Combining light modulation and frequency conversion techniques, a compact and simple frequency-stabilized optical frequency comb spanning over 45 nm in the 1.56-μm wavelength region is demonstrated. It benefits from the high-frequency stability achievable from rubidium atomic transitions at 780 nm probed in a saturation absorption scheme, which is transferred to the 1.56-μm spectral region via a second-harmonic generation process. The optical frequency comb is generated by an electro-optic modulator enclosed in a Fabry–Perot cavity that is injected by the fundamental frequency stabilized laser. Frequency stability better than 2 kHz has been demonstrated on time scales between 1000 s and 2 days both at 1560 nm, twice the rubidium wavelength, and for a comb line at 1557 nm.
  • Publication
    Accès libre
    Wavelength tuning and thermal dynamics of continuous-wave mid-IR distributed feedback quantum cascade laser
    (2013-7-17) ;
    Cappelli, Francesco
    ;
    ; ;
    Bartalini, Saverio
    ;
    We report on the wavelength tuning dynamics in continuous-wave distributed feedback quantum cascade lasers (QCLs). The wavelength tuning response for direct current modulation of two mid-IR QCLs from different suppliers was measured from 10 Hz up to several MHz using ro-vibrational molecular resonances as frequency-to-intensity converters. Unlike the output intensity, which can be modulated up to several gigahertz, the frequency-modulation bandwidth was found to be on the order of 200 kHz, limited by the laser thermal dynamics. A non-negligible roll-off and a significant phase shift are observed above a few hundred hertz already and explained by a thermal model.
  • Publication
    Accès libre
    Cross-influence between the two servo-loops of a fully-stabilized Er:fiber optical frequency comb
    We present a study of the impact of the cross-coupling between the two servo loops used to stabilize the repetition rate frep and the carrier-envelope offset (CEO) frequency fCEO in a commercial Er:fiber frequency comb, based on the combination of experimental measurements and a model of the coupled loops. The developed theoretical model enables us to quantify the influence of the servo-loop coupling on an optical comb line, by simulating the hypothetic case where no coupling would be present. Numerical values for the model were obtained from an extensive characterization of the comb, in terms of frequency noise and dynamic response to a modulation applied to each actuator, for both frep and fCEO. To validate the model, the frequency noise of an optical comb line at 1.56 μm was experimentally measured from the heterodyne beat between the comb and a cavity-stabilized ultranarrow-linewidth laser and showed good agreement with the calculated noise spectrum. The coupling between the two stabilization loops results in a more than 10-fold reduction of the comb mode frequency noise power spectral density in a wide Fourier frequency range.
  • Publication
    Accès libre
    New-generation cryogenic sapphire microwave oscillators for space, metrology and scientific applications
    (2012-8-28)
    Giordano, Vincent
    ;
    Grop, Serge
    ;
    Dubois, Benoît
    ;
    Bourgeois, Pierre-Yves
    ;
    Kersalé, Yann
    ;
    Haye, Grégory
    ;
    ; ; ; ;
    Chauvin, Jacques
    ;
    Valat, Davis
    ;
    Rubiola, Enrico
    This article reports on the characterization of cryogenic sapphireoscillators (CSOs), and on the first test of a CSO in a real field installation, where ultimate frequency stability and continuous operation are critical issues, with no survey. Thanks to low-vibration liquid-He cryocooler design, Internet monitoring, and a significant effort of engineering, these oscillators could bridge the gap from an experiment to a fully reliable machine. The cryocooler needs scheduled maintenance every 2 years, which is usual for these devices. The direct comparison of two CSOs demonstrates a frequency stability of 5 × 10E−16 for 30 s < τ < 300 s integration time, and 4.5 × 10E−15 at 1 day (1 × 10E−14 typical). Two prototypes are fully operational, codenamed ELISA and ULISS. ELISA has been permanently installed the new deep space antenna station of the European Space Agency in Malargüe, Argentina, in May 2012. ULISS is a transportable version of ELISA, modified to fit in a small van (8.5 m2 footprint). Installation requires a few hours manpower and 1 day of operation to attain full stability. ULISS, intended for off-site experiments and as a technology demonstrator, and has successfully completed two long-distance travels.
  • Publication
    Accès libre
    Experimental Validation of a Simple Approximation to Determine the Linewidth of a Laser from its Frequency Noise Spectrum
    Laser frequency fluctuations can be characterized either comprehensively by the frequency noise spectrum or in a simple but incomplete manner by the laser linewidth. A formal relation exists to calculate the linewidth from the frequency noise spectrum, but it is laborious to apply in practice. We recently proposed a much simpler geometrical approximation applicable to any arbitrary frequency noise spectrum. Here we present an experimental validation of this approximation using laser sources of different spectral characteristics. For each of them, we measured both the frequency noise spectrum to calculate the approximate linewidth and the actual linewidth directly. We observe a very good agreement between the approximate and directly measured linewidths over a broad range of values (from kilohertz to megahertz) and for significantly different laser line shapes.