Options
Di Francesco, Joab
Nom
Di Francesco, Joab
Affiliation principale
Fonction
Assistant
Identifiants
Résultat de la recherche
4 Résultats
Voici les éléments 1 - 4 sur 4
- PublicationAccès libreLinewidth of a quantum cascade laser assessed from its frequency noise spectrum and impact of the current driver(2012-4-21)
; ; ; ; ; We report on the measurement of the frequency noise properties of a 4.6-μm distributed-feedback quantum-cascade laser (QCL) operating in continuous wave near room temperature using a spectroscopic set-up. The flank of the R(14) ro-vibrational absorption line of carbon monoxide at 2196.6 cm^−1 is used to convert the frequency fluctuations of the laser into intensity fluctuations that are spectrally analyzed. We evaluate the influence of the laser driver on the observed QCL frequency noise and show how only a low-noise driver with a current noise density below ≈1 nA/√Hz allows observing the frequency noise of the laser itself, without any degradation induced by the current source. We also show how the laser FWHM linewidth, extracted from the frequency noise spectrum using a simple formula, can be drastically broadened at a rate of ≈1.6 MHz/(nA/√Hz) for higher current noise densities of the driver. The current noise of commercial QCL drivers can reach several nA/√Hz , leading to a broadening of the linewidth of our QCL of up to several megahertz. To remedy this limitation, we present a low-noise QCL driver with only 350 pA/√Hz current noise, which is suitable to observe the ≈550 kHz linewidth of our QCL. - PublicationAccès libreFrequency noise of free-running 4.6 um distributed feedback quantum cascade lasers near room temperature(2011-8-10)
; ; ; ; ;Faist, J.; The frequency noise properties of commercial distributed feedback quantum cascade lasers emitting in the 4.6 um range and operated in cw mode near room temperature (277K) are presented. The measured frequency noise power spectral density reveals a flicker noise dropping down to the very low level of <100 Hz2/Hz at 10 MHz Fourier frequency and is globally a factor of 100 lower than data recently reported for a similar laser operated at cryogenic temperature. This makes our laser a good candidate for the realization of a mid-IR ultranarrow linewidth reference. - PublicationAccès libreIntersubband spectroscopy probing higher order interminiband transitions in AlN-GaN-based superlattices(2011)
; ; ;Kandaswamy, Prem K.Monroy, EvaWe investigate midinfrared intersubband photodetectors based on short-period AlN/GaN superlattices with different quantum well thicknesses. Band structure calculations, as well as optical transmission and photovoltage measurements, underline the importance of higher order interminiband transitions. In particular, it was found that optical transitions between the second and third minibands benefit from much larger electron displacements and oscillator strengths than those between the first and second minibands. Our results suggest that optical rectification is therefore much more efficient for devices based on a higher order interminiband transition. - PublicationAccès libreInterferometric measurements beyond the coherence length of the laser source
;Salvadé, Yves ;Przygodda, Frank ;Rohner, Marcel ;Polster, Albert ;Meyer, Yves ;Monnerat, Serge ;Gloriod, Olivier ;Llera, Miguel; ; ; Interferometric measurements beyond the coherence length of the laser are investigated theoretically and experimentally in this paper. Thanks to a high-bandwidth detection, high-speed digitizers and a fast digital signal processing, we have demonstrated that the limit of the coherence length can be overcome. Theoretically, the maximal measurable displacement is infinite provided that the sampling rate is sufficiently short to prevent any phase unwrapping error. We could verify experimentally this concept using a miniature interferometer prototype, based on a frequency stabilized vertical cavity surface emitting laser. Displacement measurements at optical path differences up to 36 m could be realized with a relative stability better than 0.1 ppm, although the coherence length estimated from the linewidth and frequency noise measurements do not exceed 6.6 m.