Logo du site
  • English
  • Français
  • Se connecter
Logo du site
  • English
  • Français
  • Se connecter
  1. Accueil
  2. Université de Neuchâtel
  3. Publications
  4. Effect of source variability and transport processes on carbon isotope ratios of TCE and PCE in two sandy aquifers
 
  • Details
Options
Vignette d'image

Effect of source variability and transport processes on carbon isotope ratios of TCE and PCE in two sandy aquifers

Auteur(s)
Hunkeler, Daniel 
Centre d'hydrogéologie et de géothermie 
Chollet, N
Pittet, X.
Aravena, R
Cherry, J. A.
Parker, B. L.
Date de parution
2004
In
Journal of Contaminant Hydrology, Elsevier, 2004/274/1-4/265-282
Mots-clés
  • Chlorinated solvents
  • Groundwater
  • Stable isotopes
  • CSIA
  • Chlorinated solvents

  • Groundwater

  • Stable isotopes

  • CSIA

Résumé
Chlorinated ethenes often migrate over extended distances in aquifers and may originate from different sources. The aim of this study was to determine whether stable carbon isotope ratios remain constant during dissolution and transport of chlorinated ethenes and whether the ratios can be used to link plumes to their sources. Detailed depth-discrete delineation of the carbon isotope ratio in a tetrachloroethene (PCE) plume and in a trichloroethene (TCE) plume was done along cross-sections orthogonal to groundwater flow in two sandy aquifers in the Province of Ontario, Canada. At the TCE site, TCE concentrations up to solubility were measured in one high concentration zone close to the bottom of the aquifer from where dense non-aqueous phase liquid (DNAPL) was collected. A laboratory experiment using the DNAPL indicated that only very small carbon isotope fractionation occurs during dissolution of TCE (0.26‰), which is consistent with field observations. At most sampling points, the δ<sup>13</sup>C of dissolved TCE was similar to that of the DNAPL except for a few sampling points at the bottom of the aquifer close to the underlying aquitard. At these points, a <sup>13</sup>C enrichment of up to 2.4‰ was observed, which was likely due to biodegradation and possibly preferential diffusion of TCE with <sup>12</sup>C into the aquitard. In contrast to the TCE site, several distinct zones of high concentration were observed at the PCE site and from zones to zone, the δ<sup>13</sup>C values varied substantially from −24.3‰ to −33.6‰. Comparison of the δ<sup>13</sup>C values in the high concentration zones made it possible to divide the plume in the three different domains, each probably representing a different episode and location of DNAPL release. The three different zones could still be distinguished 220 m from the DNAPL sources. This demonstrates that carbon isotope ratios can be used to differentiate between different zones in chlorinated ethene plumes and to link plume zones to their sources. In addition, subtle variations in δ<sup>13</sup>C at plume fringes provided insight into mechanisms of plume spreading in transverse vertical direction. These variations were identified because of the high-resolution provided by the monitoring network.
Identifiants
https://libra.unine.ch/handle/123456789/18526
_
10.1016/j.jconhyd.2004.03.003
Type de publication
journal article
Dossier(s) à télécharger
 main article: Hunkeler_Daniel_-_Effect_of_source_variability_20060831.pdf (710.32 KB)
google-scholar
Présentation du portailGuide d'utilisationStratégie Open AccessDirective Open Access La recherche à l'UniNE Open Access ORCIDNouveautés

Service information scientifique & bibliothèques
Rue Emile-Argand 11
2000 Neuchâtel
contact.libra@unine.ch

Propulsé par DSpace, DSpace-CRIS & 4Science | v2022.02.00