Unnecessary interruptions of cardiac massage during simulated cardiac arrests

Auteur(s)
Marsch, Stephan
Tschan, Franziska 
Institut de psychologie du travail et des organisations 
Semmer, Norbert
Spychiger, Martin
Breuer, Marc
Hunziker, Patrick
Date de parution
2005
In
European Journal of Anaesthesiology
Vol.
11
No
22
De la page
831
A la page
833
Mots-clés
  • resuscitation
  • cardiopulmonary resuscitation
  • heart massage
  • advanced
  • life support
  • teaching
  • patient simulation
  • CARDIOPULMONARY-RESUSCITATION
  • PRECORDIAL COMPRESSION
  • resuscitation

  • cardiopulmonary resus...

  • heart massage

  • advanced

  • life support

  • teaching

  • patient simulation

  • CARDIOPULMONARY-RESUS...

  • PRECORDIAL COMPRESSIO...

Résumé
Background and objective: Cardiopulmonary resuscitation should not be interrupted until the return of spontaneous circulation or the decision to withhold further treatment. There are no data on how consistent in-hospital cardiopulmonary resuscitation is performed. Accordingly, the aim of the present study was to identify length and type of unnecessary interruptions in simulated cardiac arrests. Methods: The study was carried out in a patient simulator. A scenario of cardiac arrest due to ventricular fibrillation was used. Resuscitation teams consisted of three nurses, a resident and a staff physician. Using videotapes recorded during simulations, the activities of the teams were coded in 5-s intervals. Unnecessary interruptions were defined as any interruptions in cardiac massage of 10s or more that were not caused by defibrillation or endotracheal intubation. Results: Twelve teams were studied. The total time of possible cardiac massage was 414 +/- 125 s. In each team at least one unnecessary interruption occurred (range 1-5). Interruptions mounted up to 65 +/- 40 s (range 20-155) or 16 +/- 10% (range 5-41) of the total time of possible cardiac massage. Failure to swiftly resume cardiac massage after an unsuccessful defibrillation accounted for 14 of 39 episodes and for 44 +/- 40% of the time of unnecessary interruptions. The debriefings revealed that participants had generally not noticed the unnecessary interruptions during the simulation. Conclusions: The present study identified a significant amount of unnecessary interruptions in cardiac massage. These interruptions were not noticed by the health-care workers involved.
Identifiants
https://libra.unine.ch/handle/123456789/11475
Type de publication
journal article
google-scholar
Présentation du portailGuide d'utilisationStratégie Open AccessDirective Open Access La recherche à l'UniNE Open Access ORCIDNouveautés

Service information scientifique & bibliothèques
Rue Emile-Argand 11
2000 Neuchâtel
contact.libra@unine.ch

Propulsé par DSpace, DSpace-CRIS & 4Science | v2022.02.00