Voici les éléments 1 - 8 sur 8
  • Publication
    Métadonnées seulement
    Interferometric measurements beyond the coherence length of the laser source
    (2016-9-19) ; ; ;
    Salvadé, Yves
    ;
    Przygodda, Frank
    ;
    Rohner, Marcel
    ;
    Meyer, Yves
    ;
    Gloriot, Olivier
    ;
    Llera, Miguel
    ;
    ;
    Polster, Albert
    Interferometric measurements beyond the coherence length of the laser are investigated theoretically and experimentally in this paper. Thanks to a high-bandwidth detection, high-speed digitizers and a fast digital signal processing, we have demonstrated that the limit of the coherence length can be overcome. Theoretically, the maximal measurable displacement is infinite provided that the sampling rate is sufficiently short to prevent any phase unwrapping error. We could verify experimentally this concept using a miniature interferometer prototype, based on a frequency stabilized vertical cavity surface emitting laser. Displacement measurements at optical path differences up to 36 m could be realized with a relative stability better than 0.1 ppm, although the coherence length estimated from the linewidth and frequency noise measurements do not exceed 6.6 m.
  • Publication
    Métadonnées seulement
    Rb-stabilized laser at 1572 nm for CO2 monitoring
    We have developed a compact rubidium-stabilized laser system to serve as optical frequency reference in the 1.55-m wavelength region, in particular for CO2 monitoring at 1572 nm. The light of a fiber-pigtailed distributed feedback (DFB) laser emitting at 1560 nm is frequency-doubled and locked to a sub-Doppler rubidium transition at 780 nm using a 2-cm long vapor glass cell. Part of the DFB laser light is modulated with an electro-optical modula-tor enclosed in a Fabry-Perot cavity, generating an optical frequency comb with spectral cover-age extending from 1540 nm to 1580 nm. A second slave DFB laser emitting at 1572 nm and offset-locked to one line of the frequency comb shows a relative frequency stability of 1·10-11at 1 s averaging time and <4·10-12 from 1 hour up to 3 days.
  • Publication
    Métadonnées seulement
    DFB-ridge laser diodes at 894 nm for Cesium atomic clocks
    (2016-2-13)
    Von Bandel, N.
    ;
    Garcia, M.
    ;
    Lecomte, M.
    ;
    Larrue, A.
    ;
    Robert, Y.
    ;
    Vinet, E.
    ;
    Driss, O.
    ;
    Parilaud, O.
    ;
    Krakowski, M.
    ;
    ; ;
    Time and frequency applications are in need of high accuracy and high stability clocks. Optically pumped compact industrial Cesium atomic clocks are a promising approach that could satisfy these demands. However, the stability of these clocks relies, among others, on the performances of the laser diodes that are used. This issue has led the III-V Lab to commit to the European Euripides-LAMA project that aims to provide competitive compact optical Cesium clocks for ground applications. This work will provide key experience for further space technology qualification. III-V Lab is in charge of the design, fabrication and reliability of Distributed-Feedback diodes (DFB) at 894 nm (D1 line of Cesium) and 852 nm (D2 line). LTF-Unine is in charge of their spectral characterisation. The use of D1 line for pumping will provide simplified clock architecture compared to the D2 line pumping thanks to simpler atomic transitions and a larger spectral separation between lines in the 894 nm case. Also, D1 line pumping overcomes the issue of unpumped “idle states” that occur with D2 line. The modules should provide narrow linewidth (<1 MHz), very good reliability in time and, crucially, be less sensitive to optical feedback. The development of the 894 nm wavelength is grounded on III-V Lab results for 852 nm DFB. We show here results from Al-free active region with InGaAsP quantum well Ridge DFB lasers. We obtain the D1 Cs line (894.4 nm) at 67°C and 165 mA (optical power of 40 mW) with a high side mode suppression ratio. The wavelength evolution with temperature and current are respectively 0.06 nm/K and 0.003 nm/mA. The laser linewidth is less than 1 MHz. The Relative Intensity Noise (RIN) and the frequency noise are respectively less than 10-12 Hz-1 @ f ≥ 10 Hz and 109 Hz2/Hz @ f ≥ 10 Hz.
  • Publication
    Accès libre
    Compact rubidium-stabilized multi-frequency reference source in the 1.55-μm region
    Combining light modulation and frequency conversion techniques, a compact and simple frequency-stabilized optical frequency comb spanning over 45 nm in the 1.56-μm wavelength region is demonstrated. It benefits from the high-frequency stability achievable from rubidium atomic transitions at 780 nm probed in a saturation absorption scheme, which is transferred to the 1.56-μm spectral region via a second-harmonic generation process. The optical frequency comb is generated by an electro-optic modulator enclosed in a Fabry–Perot cavity that is injected by the fundamental frequency stabilized laser. Frequency stability better than 2 kHz has been demonstrated on time scales between 1000 s and 2 days both at 1560 nm, twice the rubidium wavelength, and for a comb line at 1557 nm.
  • Publication
    Accès libre
    Evaluation of the frequency stability of a VCSEL locked to a micro-fabricated Rubidium vapour cell
    (2010)
    Di Francesco, Joab F.
    ;
    ; ; ; ; ;
    Salvadé, Y.
    ;
    de Rooij, Nicolaas F.
    ;
    Petremand, Y.
    We present our evaluation of a compact laser system made of a 795 nm VCSEL locked to the Rubidium absorption line of a micro-fabricated absorption cell. The spectrum of the VCSEL was characterised, including its RIN, FM noise and line-width. We optimised the signal-to-noise ratio and determined the frequency shifts versus the cell temperature and the incident optical power. The frequency stability of the laser (Allan deviation) was measured using a high-resolution wavemeter and an ECDL-based reference. Our results show that a fractional instability of ≥ 10-9 may be reached at any timescale between 1 and 100'000 s. The MEMS cell was realised by dispensing the Rubidium in a glass-Silicon preform which was then, sealed by anodic bonding. The overall thickness of the reference cell is 1.5 mm. No buffer gas was added. The potential applications of this compact and low-consumption system range from optical interferometers to basic laser spectroscopy. It is particularly attractive for mobile and space instruments where stable and accurate wavelength references are needed.
  • Publication
    Accès libre
    Compact rubidium-stabilized multi-frequency reference source in the 1.55-μm region
    Combining light modulation and frequency conversion techniques, a compact and simple frequency-stabilized optical frequency comb spanning over 45 nm in the 1.56- μm wavelength region is demonstrated. It benefits from the high-frequency stability achievable from rubidium atomic transitions at 780 nm probed in a saturation absorption scheme, which is transferred to the 1.56- μm spectral region via a second-harmonic generation process. The optical frequency comb is generated by an electro-optic modulator enclosed in a Fabry–Perot cavity that is injected by the fundamental frequency stabilized laser. Frequency stability better than 2 kHz has been demonstrated on time scales between 1000 s and 2 days both at 1560 nm, twice the rubidium wavelength, and for a comb line at 1557 nm.
  • Publication
    Accès libre
    Rb-stabilized laser at 1572 nm for CO2 monitoring
    We have developed a compact rubidium-stabilized laser system to serve as optical frequency reference in the 1.55-μm wavelength region, in particular for CO2 monitoring at 1572 nm. The light of a fiber-pigtailed distributed feedback (DFB) laser emitting at 1560 nm is frequency-doubled and locked to a sub-Doppler rubidium transition at 780 nm using a 2-cm long vapor glass cell. Part of the DFB laser light is modulated with an electro-optical modulator enclosed in a Fabry-Perot cavity, generating an optical frequency comb with spectral coverage extending from 1540 nm to 1580 nm. A second slave DFB laser emitting at 1572 nm and offset-locked to one line of the frequency comb shows a relative frequency stability of 1.10-11 at 1 s averaging time and <4.10-12 from 1 hour up to 3 days.
  • Publication
    Accès libre
    Interferometric measurements beyond the coherence length of the laser source
    Salvadé, Yves
    ;
    Przygodda, Frank
    ;
    Rohner, Marcel
    ;
    Polster, Albert
    ;
    Meyer, Yves
    ;
    Monnerat, Serge
    ;
    Gloriod, Olivier
    ;
    Llera, Miguel
    ;
    ; ; ;
    Interferometric measurements beyond the coherence length of the laser are investigated theoretically and experimentally in this paper. Thanks to a high-bandwidth detection, high-speed digitizers and a fast digital signal processing, we have demonstrated that the limit of the coherence length can be overcome. Theoretically, the maximal measurable displacement is infinite provided that the sampling rate is sufficiently short to prevent any phase unwrapping error. We could verify experimentally this concept using a miniature interferometer prototype, based on a frequency stabilized vertical cavity surface emitting laser. Displacement measurements at optical path differences up to 36 m could be realized with a relative stability better than 0.1 ppm, although the coherence length estimated from the linewidth and frequency noise measurements do not exceed 6.6 m.