Options
Kang, Songbai
Nom
Kang, Songbai
Affiliation principale
Fonction
Ancien.ne collaborateur.trice
Identifiants
Résultat de la recherche
Voici les éléments 1 - 6 sur 6
- PublicationAccès libreHigh performance vapour-cell frequency standardsWe report our investigations on a compact high-performance rubidium (Rb) vapour-cell clock based on microwave-optical double-resonance (DR). These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm3 external volume. In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated. Short-term stabilities of 1.4×10-13 τ-1/2 and 2.4×10-13 τ-1/2 are measured for CW-DR and Ramsey-DR schemes, respectively. In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation. Implementations in miniature atomic clocks are considered.
- PublicationMétadonnées seulementStability limitations from optical detection in Ramsey-type vapour-cell atomic clocks(2015-10-29)
; ; ; In today's state of the art compact vapour-cell atomic clocks relying on the pulsed Ramsey-type interrogation, optical detection noise is a major limitation to the achievable short-term stability. In this communication, the influence of the optical detection time on the clock's short-term stability is investigated and a new analytical expression is developed to precisely predict the stability performance, taking into account the details of the optical detection phase of a Ramsey-type atomic clock. The theory is in good agreement with the experimental results. It is applied for evaluating the clock's shot-noise limit. - PublicationMétadonnées seulementHigh performance vapour-cell frequency standards(: Journal of Physics: Conference Series 723, 2015-10-27)
; ; ; ; ; ; We report our investigations on a compact high-performance rubidium (Rb) vapour-cell clock based on microwave-optical double-resonance (DR). These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm3 external volume. In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated. Short-term stabilities of 1.4×10^-13 τ^-1/2 and 2.4×10^-13 τ^-1/2 are measured for CW-DR and Ramsey-DR schemes, respectively. In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation. Implementations in miniature atomic clocks are considered. - PublicationAccès libreDemonstration of a high-performance pulsed optically pumped Rb clock based on a compact magnetron-type microwave cavity(2015-3-12)
; ; ; ; We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget. - PublicationAccès libreStability limitations from optical detection in Ramsey-type vapour-cell atomic clocksIn today’s state of the art compact vapour-cell atomic clocks relying on the pulsed Ramsey-type interrogation, optical detection noise is a major limitation to the achievable short-term stability. In this communication, the influence of the optical detection time on the clock’s short-term stability is investigated and a new analytical expression is developed to precisely predict the stability performance, taking into account the details of the optical detection phase of a Ramsey-type atomic clock. The theory is in good agreement with the experimental results. It is applied for evaluating the clock’s shot-noise limit.
- PublicationAccès libreDemonstration of a high-performance pulsed optically pumped Rb clock based on a compact magnetron-type microwave cavityWe demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7×10-14τ-1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock’s performance are analyzed. A short-term stability of 2.1×10-13τ-1/2 is demonstrated which is consistent with the noise budget.