High-performance laser pumped rubidium frequency standard for satellite navigation

Author(s)
Bandi, T.
Affolderbach, Christoph  
Laboratoire temps-fréquence  
Calosso, C.E.
Mileti, Gaetano  
Laboratoire temps-fréquence  
Date issued
2011
In
Electronics Letters
Vol
12
No
47
From page
698
To page
699
Abstract
Presented is a double-resonance continuous-wave laser-pumped rubidium
(Rb) atomic clock with a short-term stability of 4 × 10(-13) t(-1/2) for integration times 1 s ≤ t ≤ 1000 s, and a medium- to longterm stability reaching the 1 × 10(-14) level at 10(4) s. The clock uses an Rb vapour cell with increased diameter of 25 mm, accommodated
inside a newly developed compact magnetron-type microwave cavity.
This results in a bigger signal with reduced linewidth, and thus improved short-term stability from a clock with 1 dm(3) physics package volume only. The medium- to long-term clock stability is achieved by minimising the effects of light-shift and temperature coefficient on the atoms. Potential applications of the clock are discussed.
Publication type
journal article
Identifiers
https://libra.unine.ch/handle/20.500.14713/59810
File(s)
Loading...
Thumbnail Image
Download
Name

2016-11-09_2600_9355.pdf

Type

Main Article

Size

199.99 KB

Format

Adobe PDF

Université de Neuchâtel logo

Service information scientifique & bibliothèques

Rue Emile-Argand 11

2000 Neuchâtel

contact.libra@unine.ch

Service informatique et télématique

Rue Emile-Argand 11

Bâtiment B, rez-de-chaussée

Powered by DSpace-CRIS

libra v2.1.0

© 2025 Université de Neuchâtel

Portal overviewUser guideOpen Access strategyOpen Access directive Research at UniNE Open Access ORCIDWhat's new