  4. A cold-atom Ramsey clock with a low volume physics package

A cold-atom Ramsey clock with a low volume physics package

Author(s)
Alan Bregazzi
Batori, Etienne  
Faculté des sciences  
Affolderbach, Christoph  
Laboratoire temps-fréquence  
Mileti, Gaetano  
Laboratoire temps-fréquence  
Paul Griffin
Ben Lewis
Erling Riis
Date issued
January 9, 2024
Abstract
We demonstrate a Ramsey-type microwave clock interrogating the 6.835~GHz ground-state transition in cold \textsuperscript{87}Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of 1.5×10−11~τ−1/2 is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of ≈67~cm\textsuperscript{3}, ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.
Publication type
preprint
Identifiers
https://libra.unine.ch/handle/20.500.14713/29858
DOI
10.48550/arXiv.2305.02944
File(s)
Loading...
Thumbnail Image
Download
Name

s41598-024-51418-8.pdf

Type

Main Article

Size

1.23 MB

Format

Adobe PDF

Université de Neuchâtel logo

Service information scientifique & bibliothèques

Rue Emile-Argand 11

2000 Neuchâtel

contact.libra@unine.ch

Service informatique et télématique

Rue Emile-Argand 11

Bâtiment B, rez-de-chaussée

Powered by DSpace-CRIS

libra v2.1.0

© 2025 Université de Neuchâtel

Portal overviewUser guideOpen Access strategyOpen Access directive Research at UniNE Open Access ORCIDWhat's new