Repository logo
Research Data
Publications
Projects
Persons
Organizations
English
Français
Log In(current)
  1. Home
  2. Publications
  3. Article de recherche (journal article)
  4. Influence of reservoir geology on seismic response during decameter-scale hydraulic stimulations in crystalline rock

Influence of reservoir geology on seismic response during decameter-scale hydraulic stimulations in crystalline rock

Author(s)
Villiger, Linus
Gischig, Valentin
Doetsch, J.
Krietsch, Hannes
Dutler, Nathan  
Faculté des sciences  
Jalali, Mohammadreza
Valley, Benoît  
Laboratoire de géothermie et géomécanique des réservoirs  
Selvedurai, P. A.
Mignan, Arnaud
Plenkers, K.
Giardini, Domenico
Amann, Florian
Wiemer, Stefan
Date issued
April 28, 2020
In
Solid Earth
No
X
From page
627
To page
655
Reviewed by peer
1
Abstract
We performed a series of 12 hydraulic stimulation experiments in a 20 m×20 m×20 m foliated, crystalline rock volume intersected by two distinct fault sets at the Grimsel Test Site, Switzerland. The goal of these experiments was to improve our understanding of stimulation processes associated with high-pressure fluid injection used for reservoir creation in enhanced or engineered geothermal systems. In the first six experiments, pre-existing fractures were stimulated to induce shear dilation and enhance permeability. Two types of shear zones were targeted for these hydroshearing experiments: (i) ductile ones with intense foliation and (ii) brittle–ductile ones associated with a fractured zone. The second series of six stimulations were performed in borehole intervals without natural fractures to initiate and propagate hydraulic fractures that connect the wellbore to the existing fracture network. The same injection protocol was used for all experiments within each stimulation series so that the differences observed will give insights into the effect of geology on the seismo-hydromechanical response rather than differences due to the injection protocols. Deformations and fluid pressure were monitored using a dense sensor network in boreholes surrounding the injection locations. Seismicity was recorded with sensitive in situ acoustic emission sensors both in boreholes and at the tunnel walls. We observed high variability in the seismic response in terms of seismogenic indices, b values, and spatial and temporal evolution during both hydroshearing and hydrofracturing experiments, which we attribute to local geological heterogeneities. Seismicity was most pronounced for injections into the highly conductive brittle–ductile shear zones, while the injectivity increase on these structures was only marginal. No significant differences between the seismic response of hydroshearing and hydrofracturing was identified, possibly because the hydrofractures interact with the same pre-existing fracture network that is reactivated during the hydroshearing experiments. Fault slip during the hydroshearing experiments was predominantly aseismic. The results of our hydraulic stimulations indicate that stimulation of short borehole intervals with limited fluid volumes (i.e., the concept of zonal insulation) may be an effective approach to limit induced seismic hazard if highly seismogenic structures can be avoided.
Project(s)
Hydraulic fracturing during the ISC experiment  
Publication type
journal article
Identifiers
https://libra.unine.ch/handle/20.500.14713/64306
DOI
10.5194/se-11-627-2020
File(s)
Loading...
Thumbnail Image
Download
Name

2022-12-19_1992_3985.pdf

Type

Main Article

Size

13.97 MB

Format

Adobe PDF

Université de Neuchâtel logo

Service information scientifique & bibliothèques

Rue Emile-Argand 11

2000 Neuchâtel

contact.libra@unine.ch

Service informatique et télématique

Rue Emile-Argand 11

Bâtiment B, rez-de-chaussée

Powered by DSpace-CRIS

libra v2.2.0

© 2026 Université de Neuchâtel

Portal overviewUser guideOpen Access strategyOpen Access directive Research at UniNE Open Access ORCIDWhat's new