Voici les éléments 1 - 6 sur 6
Pas de vignette d'image disponible
Publication
Accès libre

A Microcell Atomic Clock Based on a Double-Resonance Ramsey Scheme

2022, Batori, Etienne, Affolderbach, Christoph, Pellaton, Matthieu, Gruet, Florian, Maddalena Violetti, Yuanyan Su, Anja K. Skrivervik, Mileti, Gaetano

Pas de vignette d'image disponible
Publication
Accès libre

Rb vapor-cell clock demonstration with a frequency-doubled telecom laser

, Almat, Nil, Pellaton, Matthieu, Moreno, William, Gruet, Florian, Affolderbach, Christoph, Mileti, Gaetano

We employ a recently developed laser system, based on a low-noise telecom laser emitting around 1.56 μm, to evaluate its impact on the performance of an Rb vapor-cell clock in a continuous-wave double-resonance scheme. The achieved short-term clock instability below 2.5·10−13·τ−1∕2 demonstrates, for the first time, the suitability of a frequency-doubled telecom laser for this specific application. We measure and study quantitatively the impact of laser amplitude and frequency noises and of the ac Stark shift, which limit the clock frequency stability on short timescales. We also report on the detailed noise budgets and demonstrate experimentally that, under certain conditions, the short-term stability of the clock operated with the low-noise telecom laser is improved by a factor of three compared to clock operation using the direct 780-nm laser.

Pas de vignette d'image disponible
Publication
Accès libre

High performance vapour-cell frequency standards

2016-6-1, Gharavipour, Mohammadreza, Affolderbach, Christoph, Kang, Songbai, Pellaton, Matthieu, Mileti, Gaetano, Bandi Nagabhushan, Thejesh, Gruet, Florian

We report our investigations on a compact high-performance rubidium (Rb) vapour-cell clock based on microwave-optical double-resonance (DR). These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm3 external volume. In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated. Short-term stabilities of 1.4×10-13 τ-1/2 and 2.4×10-13 τ-1/2 are measured for CW-DR and Ramsey-DR schemes, respectively. In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation. Implementations in miniature atomic clocks are considered.

Pas de vignette d'image disponible
Publication
Accès libre

Characterization of Frequency-Doubled 1.5-μm Lasers for High-Performance Rb Clocks

, Almat, Nil, Moreno, William, Pellaton, Matthieu, Gruet, Florian, Affolderbach, Christoph, Mileti, Gaetano

We report on the characterization of two fiber-coupled 1.5- μm diode lasers, frequency-doubled and stabilized to Rubidium (Rb) atomic resonances at 780 nm. Such laser systems are of interest in view of their implementation in Rb vaporcell atomic clocks, as an alternative to lasers emitting directly at 780 nm. The spectral properties and the instabilities of the frequency-doubled lasers are evaluated against a state-of-the-art compact Rb-stabilized laser system based on a distributed-feedback laser diode emitting at 780 nm. All three lasers are frequency stabilized using essentially identical Doppler-free spectroscopy schemes. The long-term optical power fluctuations at 780 nm are measured, simultaneously with the frequency instability measurements done by three beat notes established between the three lasers. One of the frequency-doubled laser systems shows at 780 nm excellent spectral properties. Its relative intensity noise <10−12 Hz−1 is one order of magnitude lower than the reference 780-nm laser, and the frequency noise <106 Hz2/Hz is limited by the laser current source. Its optical frequency instability is <4 × 10−12 at τ = 1 s, limited by the reference laser, and better than 1 × 10−11 at all timescales up to one day. We also evaluate the impact of the laser spectral properties and instabilities on the Rb atomic clock performance, in particular taking into account the light-shift effect. Optical power instabilities on long-term timescales, largely originating from the frequency-doubling stage, are identified as a limitation in view of high-performance Rb atomic clocks.

Pas de vignette d'image disponible
Publication
Métadonnées seulement

High performance vapour-cell frequency standards

2015-10-27, Gharavipour, Mohammadreza, Affolderbach, Christoph, Kang, Songbai, Bandi Nagabhushan, Thejesh, Gruet, Florian, Pellaton, Matthieu, Mileti, Gaetano

We report our investigations on a compact high-performance rubidium (Rb) vapour-cell clock based on microwave-optical double-resonance (DR). These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm3 external volume. In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated. Short-term stabilities of 1.4×10^-13 τ^-1/2 and 2.4×10^-13 τ^-1/2 are measured for CW-DR and Ramsey-DR schemes, respectively. In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation. Implementations in miniature atomic clocks are considered.

Pas de vignette d'image disponible
Publication
Accès libre

Impact of microwave-field inhomogeneity in an alkali vapour cell using Ramsey double-resonance spectroscopy

, Moreno, William, Pellaton, Matthieu, Affolderbach, Christoph, Almat, Nil, Gruet, Florian, Mileti, Gaetano

We numerically and experimentally evaluate the impact of the inhomogeneity of the microwave field in the cavity used to perform double-resonance (DR) Ramsey spectroscopy in a buffer gas alkali vapour cell. The Ramsey spectrum is numerically simulated using a simple theoretical model and taking into account the field distribution in a magnetron-type microwave resonator. An experimental evaluation is performed using a DR pulsed optically pumped (POP) atomic clock. It is shown that the sensitivity to the micro-wave power of the DR POP clock can be reproduced from the combination of two inhomogeneities across the vapour cell: microwave field inhomogeneity and atomic ground-state resonance frequency inhomogeneity. Finally, we present the existence of an optimum operation point for which the microwave power sensitivity of our DR POP clock is reduced by two orders of magnitude. It leads into a long-term frequency stability of 1 × 10-14.