Compound-Specific Chlorine Isotope Analysis: A Comparison of Gas Chromatography/Isotope Ratio Mass Spectrometry and Gas Chromatography/Quadrupole Mass Spectrometry Methods in an Interlaboratory Study

Author(s)
Bernstein, A
Shouakar-Stash, O
Ebert, K
Laskov, C
Hunkeler, Daniel  
Laboratoire d'hydrochimie et de contaminants  
Jeannottat, Simon
Sakaguchi-Söder, K
Laaks, J
Jochmann, M.A
Cretnik, S
Jager, J
Haderlein, S.B
Schmidt, T.C
Aravena, R
Elsner, M
Date issued
2011
In
Analytical Chemistry, American Chemical Society, 2011/83//7624-7634
Abstract
Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of <sup>37</sup>Cl/<sup>35</sup> Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ<sup>37</sup>Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1%), to GC/qMS (1σ ≈0.2_0.5%for Agilent GC/qMS and 1σ≈0.2_0.9%for Thermo GC/qMS). Nonetheless, δ<sup>37</sup>Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications.
Publication type
journal article
Identifiers
https://libra.unine.ch/handle/20.500.14713/57146
DOI
10.1021/ac200516c
File(s)
Loading...
Thumbnail Image
Download
Name

Bernstein_A-Compound-specific_chlorine_isotope-20170620.pdf

Type

Main Article

Size

988.63 KB

Format

Adobe PDF

Université de Neuchâtel logo

Service information scientifique & bibliothèques

Rue Emile-Argand 11

2000 Neuchâtel

contact.libra@unine.ch

Service informatique et télématique

Rue Emile-Argand 11

Bâtiment B, rez-de-chaussée

Powered by DSpace-CRIS

libra v2.1.0

© 2026 Université de Neuchâtel

Portal overviewUser guideOpen Access strategyOpen Access directive Research at UniNE Open Access ORCIDWhat's new