Repository logo
Research Data
Publications
Projects
Persons
Organizations
English
Français
Log In(current)
  1. Home
  2. Publications
  3. Article de recherche (journal article)
  4. Frequency noise correlation between the offset frequency and the mode spacing in a mid-infrared quantum cascade laser frequency comb

Frequency noise correlation between the offset frequency and the mode spacing in a mid-infrared quantum cascade laser frequency comb

Author(s)
Shehzad, Atif  
Faculté des sciences  
Brochard, Pierre  
Laboratoire temps-fréquence  
Matthey-De-L'Endroit, Renaud  
Laboratoire temps-fréquence  
Kapsalidis, Filippos
Shahmohammadi, Mehran
Beck, Mattias
Hugi, Andreas
Jouy, Pierre
Faist, Jérôme
Südmeyer, Thomas  
Laboratoire temps-fréquence  
Schilt, Stephane  
Laboratoire temps-fréquence  
Date issued
2020
In
Optics Express, Optical Society of America
Vol
28
No
6
From page
8200
To page
8210
Abstract
The generation of frequency combs in the mid-infrared (MIR) spectral range by quantum cascade lasers (QCLs) has the potential for revolutionizing dual-comb multi-heterodyne spectroscopy in the molecular fingerprint region. However, in contrast to frequency combs based on passively mode-locked ultrafast lasers, their operation relies on a completely different mechanism resulting from a four-wave mixing process occurring in the semiconductor gain medium that locks the modes together. As a result, these lasers do not emit pulses and no direct self-referencing of a QCL comb spectrum has been achieved so far. Here, we present a detailed frequency noise characterization of a MIR QCL frequency comb operating at a wavelength of 8 μm with a mode spacing of ~ 7.4 GHz. Using a beat measurement with a narrow-linewidth single-mode QCL in combination with a dedicated electrical scheme, we measured the frequency noise properties of an optical mode of the QCL comb, and indirectly of its offset frequency for the first time, without detecting it by the standard approach of nonlinear interferometry applied to ultrafast mode-locked lasers. In addition, we also separately measured the noise of the comb mode spacing extracted electrically from the QCL. We observed a strong anti-correlation between the frequency fluctuations of the offset frequency and mode spacing, leading to optical modes with a linewidth slightly below 1 MHz in the free-running QCL comb (at 1-s integration time), which is narrower than the individual contributions of the offset frequency and mode spacing that are at least 2 MHz each.
Publication type
journal article
Identifiers
https://libra.unine.ch/handle/20.500.14713/65632
DOI
10.1364/OE.385849
File(s)
Loading...
Thumbnail Image
Download
Name

Shehzad_A_Frequency_noise_20200310.pdf

Type

Main Article

Size

985.32 KB

Format

Adobe PDF

Université de Neuchâtel logo

Service information scientifique & bibliothèques

Rue Emile-Argand 11

2000 Neuchâtel

contact.libra@unine.ch

Service informatique et télématique

Rue Emile-Argand 11

Bâtiment B, rez-de-chaussée

Powered by DSpace-CRIS

libra v2.1.0

© 2026 Université de Neuchâtel

Portal overviewUser guideOpen Access strategyOpen Access directive Research at UniNE Open Access ORCIDWhat's new