  4. Measurement with an automated oscillometric wrist device with position sensor leads to lower values than measurements obtained with an automated oscillometric arm device from the same manufacturer in elderly persons

Measurement with an automated oscillometric wrist device with position sensor leads to lower values than measurements obtained with an automated oscillometric arm device from the same manufacturer in elderly persons

Author(s)
Guggiari, Céline
Büla, Christophe
Iglesias, Katia  
Chaire d'études transnationales  
Waeber, Bernard
Date issued
2014
In
Blood Pressure Monitoring, Wolters Kluwer, 2014/19/11/32-37
Subjects
arm device elderly population oscillometric blood pressure measuring device position sensor reliability self-measurement of blood pressure validated devices wrist device
Abstract
<b>Objective : </b> Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. <br> <b>Methods : </b> Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. <br> <b>Results : </b> Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. <br> <b>Conclusion : </b>Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Publication type
journal article
Identifiers
https://libra.unine.ch/handle/20.500.14713/56151
DOI
10.1097/MBP.0000000000000013
File(s)
Loading...
Thumbnail Image
Download
Name

Iglesias_Katia_-_Measurement_with_an_automated_oscillometric_wrist_device_20160427.pdf

Type

Main Article

Size

700.8 KB

Format

Adobe PDF

Université de Neuchâtel logo

Service information scientifique & bibliothèques

Rue Emile-Argand 11

2000 Neuchâtel

contact.libra@unine.ch

Service informatique et télématique

Rue Emile-Argand 11

Bâtiment B, rez-de-chaussée

Powered by DSpace-CRIS

libra v2.1.0

© 2026 Université de Neuchâtel

Portal overviewUser guideOpen Access strategyOpen Access directive Research at UniNE Open Access ORCIDWhat's new